Closing Nonconformities Before the Certification Body Arrives
This lesson addresses a critical phase: preparing for your external certification audit. If your internal audit or management review has identified nonconformities, you need to address them before the certification body arrives. This lesson covers how to close nonconformities and prepare evidence that demonstrates conformity.
Understanding Nonconformity Severity
Nonconformities are classified as major or minor. A major nonconformity is a failure to implement a requirement of ISO 42001 or a significant breach of your documented controls. If your policy says “All high-risk systems require governance committee approval” but you find that high-risk systems have been deployed without approval, that is a major nonconformity.
A minor nonconformity is a small deviation or isolated gap. If you have implemented a model approval process correctly but one deployment lacks documentation due to administrative oversight, that is a minor nonconformity.
During Stage 2 certification audit, major nonconformities will prevent you from achieving certification. Even two or three minor nonconformities can lead to a certification refusal if they suggest systemic weakness. Your goal before Stage 2 is to close all nonconformities or demonstrate a clear path to closure.
Corrective Action Plans
For each nonconformity, develop a detailed corrective action plan. This plan should include: root cause analysis (why did this nonconformity occur?), the corrective action (what will be changed), responsible person, target completion date, and how you will verify that the nonconformity is closed.
Example: Nonconformity “Training records for AI governance team are not complete. Three of eight team members lack documented training completion records.”
Root cause: When new team members join, training completion is not consistently tracked in the documentation system.
Corrective action: Implement a training tracking log that all managers must complete for new AI team members. Track completion dates and topics. Designate the AI governance lead as custodian of the log. Conduct a one-time review of all team members to complete missing records.
Responsible: AI Governance Lead.
Target completion: 30 days.
Verification: Audit the training log quarterly; 100% completion target.
Evidence of Closure
Nonconformity closure is verified by evidence. Do not just claim a nonconformity is closed; provide evidence that the issue has been addressed.
If the nonconformity was “Model documentation is missing for three systems”, provide evidence of closure by showing completed model documentation for those three systems. If the nonconformity was “Risk assessment has not been conducted”, provide evidence by submitting the completed risk register.
Auditors will verify this evidence during Stage 2. Evidence that is vague, incomplete or post-dated (created just before the audit) will not be accepted. Genuine evidence is created during normal operations as the control is executed.
Systemic vs. Isolated Issues
When you find a nonconformity, assess whether it is isolated or systemic. An isolated issue is a one-time gap (one model lacks documentation due to administrative error). A systemic issue is a process failure that affects multiple instances (model approval process is not being followed consistently across the organisation).
Systemic issues require more significant corrective action. If three of five recent deployments lacked approval, you should not just approve those three retroactively. Instead, you should redesign the approval process, ensure it is documented clearly, train people on it, and implement a checking mechanism (e.g., a pre-deployment checklist).

Timing for Closure
Aim to close nonconformities at least two to four weeks before your Stage 2 audit. This gives you time to verify closure and to correct any new issues that emerge. If you close nonconformities on the day of Stage 2 audit, auditors will view this with suspicion. Have evidence of closure well in place beforehand.
Preventing New Nonconformities
As you close nonconformities, be mindful of not creating new ones. If you hastily redesign a process to close one nonconformity, verify that the new process is properly documented, communicated and understood before you submit it as evidence of closure.
Communication to the Certification Body
Many certification bodies allow you to submit evidence of nonconformity closure before Stage 2 audit. Check with your chosen body about their protocol. Submitting evidence of closure proactively demonstrates transparency and reduces uncertainty during the audit.
If your internal audit identified issues but you have addressed them with credible corrective actions and evidence, you can tell the certification body, “Our internal audit found X nonconformity. We have implemented corrective action Y. Here is evidence of closure. We are confident this nonconformity is resolved and we are ready for Stage 2 audit.”
Audit Readiness Checklist
Before Stage 2, work through a readiness checklist: All nonconformities from internal audit are closed or have documented closure plans. All documentation (policy, procedures, SOA) is current and version controlled. All key records (risk assessments, audit reports, monitoring metrics) are accessible and complete. All personnel in governance roles are trained on their responsibilities. The management review has been conducted and records are complete.
Thorough preparation for the certification audit is not about hiding problems. Instead, it shows that your management system is mature, problems are addressed promptly, and continuous improvement is embedded in your approach.